> joists, etc. Given that RF tends to flow on the surface of the
> conductor, how do people think this would work for RF grounding
> purposes, e.g., for connection between the rig and the ground bus? It's
> much cheaper and more readily available than copper braid.

Alan,

I don't know why anyone would want to use copper braid for a ground
connection anyway unless the connection had to be very flexible, since even
clean shiny braiding compacted together with a cable lay has about 3-4 times
the RF resistance of a similar solid conductor. Of course dense weaves and
dirty braid is much worse, a typical braid off RG-8 cable after some age
with loose lay has about the same RF resistance as a #12-16 solid copper
wire.

I wouldn't think the copper plated strap (if it is real copper) would be
anywhere near as bad as braiding. maybe someone here has measured some.