Karlnet
[Top] [All Lists]

Re: [Karlnet] KN with externally controlled STP

To: Karlnet Mailing List <karlnet@wispnotes.com>
Subject: Re: [Karlnet] KN with externally controlled STP
From: Roger Boggs <rogerboggs@att.net>
Reply-to: Karlnet Mailing List <karlnet@WISPNotes.com>
Date: Tue, 03 Jun 2003 05:51:29 -0400
List-post: <mailto:karlnet@WISPNotes.com>
Setup|Bridge Setup|Advanced Features|Enable Learned Table Lockdown?

Then reboot, and it should remain pretty stupid, shouldn't it?

At 09:36 PM 6/3/03 +1200, you wrote:
Has anyone used KN bridge's (RG's in point-point mode) in an STP scenario?
(triangle loop to be precise)
We need to use STP enabled switches rather than the KN onboard STP feature.
KN's STP works fine on its own, however when disabled and the switches are
added - the entire combo crashes and burns.
When replaced with cat5 cable on the test bench it works fine.
Im guessing this is due to the fact that Karlnet'd RG's are learning
bridges.

Is there any way to turn off the learn feature thus creating a wireless link
as-close-as-you-can-get to a length of dumb cat5 cable?

-Sam

Roger Boggs


<Prev in Thread] Current Thread [Next in Thread>