Karlnet
[Top] [All Lists]

RE: [Karlnet] Help - Can a SEC client load Run WEPPlus?

To: "Karlnet Mailing List" <karlnet@wispnotes.com>
Subject: RE: [Karlnet] Help - Can a SEC client load Run WEPPlus?
From: "Ian Hastie-Linkit" <ian@linkit.co.nz>
Reply-to: ian@linkit.co.nz, Karlnet Mailing List <karlnet@WISPNotes.com>
Date: Tue, 18 Mar 2003 21:36:19 +1200
List-post: <mailto:karlnet@WISPNotes.com>
Thanks Larry,

That explains my bench test results yesterday.
When bridging the SEC just doesnt pass anything wireless - wired. You can
ping & Manage the SEC from the AP and Ping and manage the SEC from the wired
side of the SEC but nothing in between.

I'll try it to a BG2000 tomorrow  with NAT enabled or some routing set.

Karlnet are not exactly bursting with a response so far either so I'll just
have to work it out for myself again.

Regards
Ian Hastie
LINKIT
NEW ZEALAND

www.linkit.co.nz

-----Original Message-----
From: karlnet-bounces@WISPNotes.com
[mailto:karlnet-bounces@WISPNotes.com]On Behalf Of Larry Yunker (Cyber
Broadcasting)
Sent: Tuesday, March 18, 2003 12:41 AM
To: ian@linkit.co.nz; Karlnet Mailing List
Subject: Re: [Karlnet] Help - Can a SEC client load Run WEPPlus?


As far as I am aware, a Karlnet SEC client can connect to any 802.11b
compliant AP when the CPE is placed in routing-mode or when the CPE is
placed in NAT-mode.  Bridging mode is different.

A Karlnet SEC CPE will only bridge through a Karlnet SEC AP.  I do not know
if Karlnet has a SEC AP firmware that supports WEPPlus.  That would be a
question for Karlnet themselves.

Good Luck.
Larry

----- Original Message -----
From: "Ian Hastie-Linkit" <ian@linkit.co.nz>
To: "Karlnet Mailing List" <karlnet@WISPNotes.com>
Sent: Sunday, March 16, 2003 2:38 PM
Subject: [Karlnet] Help - Can a SEC client load Run WEPPlus?


> Objective: to use an RG SEC as a client bridge to a WEPPlus enabled AP.
>
> First steps on the bench is using the Silver cards and I will use GOld
cards
> once I know it works OK.
>
> So I have just setup an RG SEC Client running (SR4500) with an Orinocco
> Silver card
> I set up an RG as an AP500 Access Point.
> Both Silver cards were loaded with WSU10872 for the lastest WEP
> drivers.(WEPPlus ready)
>
> I can ping Wired side of the AP all the way down the the RG SEC IP address
> but cannot ping anything beyond there on its wired side.
> All are set to bridge on the same subnet, same network name, NO WEP
enabled
> at this stage.
>
> I have;
> - reinstalled the SEC load just in case, setting the card for 802.11b
> wireless.
> - The configurator monitor shows the port is forwarding and have a wired
> client attached each
>    side.
> - Tested all cables end PC- end PC & all Link lights are on.
> - RF LINK tests work OK Both ways, Client can see the AP and AP can see
the
> Client but no TCP/IP
>   traffic passing.
> - I cannot manage the AP from the SEClient wired side however yet it can
see
> the RF Link from the
>   AP.
> - I can manage the AP and SEClient RG's from the wired side of the AP.
>
> I will take the Silver cards back to WSU8.10 and check it works as I have
> other RG's working this way.
>
> Anyone done this before? Anything I missed?
>
> I suspect the Latest Prox/orinoco WSU isnt Karlnet compatible.
>
>
> Regards
> Ian Hastie
> LINKIT
> NEW ZEALAND
>
> www.linkit.co.nz
>
> _______________________________________________
> Karlnet mailing list
> Karlnet@WISPNotes.com
> http://lists.wispnotes.com/mailman/listinfo/karlnet
>
>


_______________________________________________
Karlnet mailing list
Karlnet@WISPNotes.com
http://lists.wispnotes.com/mailman/listinfo/karlnet



<Prev in Thread] Current Thread [Next in Thread>