To Ten-Tec Orion users,

I got my Orion in on Friday, 12 March 2004. After a lot of thought I fabricated my own serial cable today using a DB-9 male plug at the Orion (configured as per Ten-Tec). On the other end of the 4-conductor shielded cable I placed a male DB-25 as this is what I needed.

I configured CT 10.00.002 for 57,600 baud on COM2. The program works great just like it did for the OMNI VI-Plus I previously owned. The cable is configured for "hardware handshaking" for the data flow. The "straight through" cable provided by Ten-Tec will most likely not work? Is this correct?

Serial data out from the Orion (DB-9 pin 2) goes to RXD (pin3 on the DB-25)

Serial data in from the Orion (DB-9 pin 3) goes to TXD (pin 2 on the DB-25)

Ground on the Orion (DB-9 pin 5) goes to Ground (Pin 7 on the DB-25)

RTS (in) on the Orion (DB-9 pin 7) goes to RTS out (pin 4 on the DB-25)

CTS (out) on the Orion (DB-9 pin 8) goes to CTS in (pin 5 on the DB-25)

73,

John, W4NU
Atlanta
K4JAG 1959 to 1998