CT-User
[Top] [All Lists]

[ct-user] [Fwd: CT Interface with PK-232]

To: <ct-user@contesting.com>
Subject: [ct-user] [Fwd: CT Interface with PK-232]
From: Randy Powell" <w6sw@jps.net (Randy Powell)
Date: Sun, 25 Oct 1998 18:14:49 -0800
Hi David -- I, too, had a hell of a time getting hooked up with a PK232MBX
to CT.  Here's our procedure:

turn off the PK232
start CT and set COM ports, multi-op etc to get packe window ua with ALT-T
turn on PK232 TNC and type ******* (Enter) util the PKT and CMD LED's come
on.  You should now see a welcome message.
Type MY (your call) (Enter)
Type RESTART (Enter) You should see the CHECKSUM message appear.
Type C (DXpacketcluster node callsign) (Enter).  The CON LED's should come
on and you should see the welcome message from the node.  You are in
business, we hope.

73, Randy W6SW

thanks to Larry Amodeo

-----Original Message-----
From: owner-ct-user@contesting.com
[mailto:owner-ct-user@contesting.com]On Behalf Of David F. Otey
Sent: Saturday, October 24, 1998 10:36 PM
To: ct-user@contesting.com
Subject: [ct-user] [Fwd: CT Interface with PK-232]


Hello all CTers, Perhaps my request (below) will finally make it to
distribution!  73.


--
Submissions:              ct-user@contesting.com
Administrative requests:  ct-user-REQUEST@contesting.com
WWW:                      http://www.contesting.com/ct/
Questions:                owner-ct-user@contesting.com


<Prev in Thread] Current Thread [Next in Thread>