Hi Alfred
We had similar problems when we went over 2 com ports at ZM2K. The answer
we found was that you need to configure for different IRQ's - ie you can't
share them.
73's
Murray ZL2IQ
----------
> From: Alfred J. Frugoli <ke1fo@contesting.com>
> To: CT-User Reflector <ct-user@ve7tcp.ampr.org>
> Subject: [ct-user] CT, Com Ports, IRQ's and headaches
To: <ct-user@contesting.com>
> Date: Saturday, 29 March 1997 03:24
>
> I'm trying to get CT set up using 4 com ports (2 are new). I never had
> any problems running with just 2, but more computer control stuff euqals
> more com ports. Base addresses are standard, and com 1&3 are IRQ 4 (I
> think) and com 2&4 are IRQ 3 (at any rate, the com ports share irq's).
> The comtsr programs are set up to show the proper IRQ's and base
> addresses, but when I try to use the two com ports that share an IRQ,
> neither device works properly. Do I need to configure for individual
> IRQ's? The software interrupts on the comtsr programs are all different
> for the 4 com ports.
>
> Thoughts? suggestions? I'm going to be putting together a 486 over the
> summer, and will start off right with an 8 port board! Thanks.
> --
> Al, KE1FO, ex. KE6BER mailto:ke1fo@contesting.com or ke6ber@tiac.net
> Check out my web page, http://www.tiac.net/users/ke6ber for summaries
> from the contest reflector and a growing list of amateur radio links.
>
> --
> Submissions: ct-user@ve7tcp.ampr.org
> Administrative requests: ct-user-REQUEST@ve7tcp.ampr.org
> WWW: http://www.ve7tcp.ampr.org/Software/ct
> Questions: owner-ct-user@ve7tcp.ampr.org
--
Submissions: ct-user@ve7tcp.ampr.org
Administrative requests: ct-user-REQUEST@ve7tcp.ampr.org
WWW: http://www.ve7tcp.ampr.org/Software/ct
Questions: owner-ct-user@ve7tcp.ampr.org
|