On Sun, 2006-09-24 at 22:15, peter.voelpel wrote:
> We do that as well at DF0CG/DR1A.
> One 20KVA supply for amps with 2xQB5/1750, similar to 4-400A but a bit
> bigger (500W dissipation).
K4VX also uses monoband amps, though with separate power supplies. One
problem with the single-supply design is that a single failure puts
*all* bands on low power, not just one band. (and with separate
supplies, if you have a failure on one supply/band you can use an
off-the-shelf commercial amp to fill in. With a single supply, you need
six<g>.)
ISTR W0AIH also uses multiple monoband amps.
--
Doug Smith W9WI
Pleasant View (Nashville), TN EM66
http://www.w9wi.com