CQ-Contest
[Top] [All Lists]

Re: [CQ-Contest] 62 ohm coax cable

To: <cq-contest@contesting.com>
Subject: Re: [CQ-Contest] 62 ohm coax cable
From: <jukka.klemola@nokia.com>
Date: Mon, 12 Dec 2005 15:04:12 +0200
List-post: <mailto:cq-contest@contesting.com>
 

>-----Original Message-----
>From: cq-contest-bounces@contesting.com 
..
>David Pruett
>Sent: 12 December, 2005 05:54
...
>
>50 ohm in ]================={}=================[ 75 ohm load
>                 .0818w             .0818w
>                 75 ohm             50 ohm
>
>Because there are frequency-specific lengths of coax involved, 
>it's obviously a single-band system.  I've had these for 
>almost two decades at K8CC with no failures.  No ferrite 
>involved, but you do tend to get a lot of practice installing PL-259s.
>
...
>73,
>
>Dave/K8CC

?
What for do you need the many connectors?

Just solder the coaxes and use one connector at each end of the line
i.e. at 50 ohm points.


Or did I mis-understand this somehow?


73,
Jukka OH6LI