Hello All
Some really good thoughts out there already. I have done it three time and each
one is a little better.
Walls: Sheet Rock and Drop ceiling tiles, I also insulate wall and ceiling for
sound deadening.
Lighting: I use Fluorescent lighting for setup and general use. However for
operating I prefer bouncing light off the ceiling tiles. This give nice soft
lighting.
Wiring: I have done several things about wiring the station over the years but
finally went to a wire closesit with 2" X 8" slots to pass cables through at
each operation position. I even put almost all the 120V and 240V outlets in the
wiring closesit. Should you deside to disconnenct it sure is easy. I have one
240V and 8 120V outlets at each position all in the wiring closesit. I don't
always use them all but find use for probably 6 pretty easy. I put ethernet in
the wall and used shielded cable for what it is worth. I ground through the
concrete, in my case I CAD welded them together as the house was built.
I use indoor/outdoor capeting, but it is a pain if you drop something small. I
seach it out with a bringht light.
73 Paul
K4JA
|