Hello...,
first of all thanks for the trigger about the insulated wires.
This started me to do some experiments with my 4nec2 package
in which a few months ago included the possibility to specify
radius- and material info for insulated wires.
Unfortional this showed up there was bug in the internal formula to
create the LD2 card for specifying the distributed L resulting from
the insulation layer. (thanks to RA9MB/UA3AVR and L.B.Cebik for the
additional info about the subject).
After this version 5.3.9 bug was fixed I modelled a 40 meter dipole
above average ground using 2.5 mm sq. copper wire (radius 0.892 mm)
with a 0.5 mm thick layer of hard PVC (diel-const about 4.5).
This showed up a resonant length of 10.419 meter for the bare copper
wire and a resonant length of 10.158 meter for the insulated wire, resulting
in shortening factor of about 0.975
Maybe this is of interest.... :-)
Arie.
--
(Please ignore the advertisements below)
"Sie haben neue Mails!" - Die GMX Toolbar informiert Sie beim Surfen!
Jetzt aktivieren unter http://www.gmx.net/info
_______________________________________________
Antennaware mailing list
Antennaware@contesting.com
http://lists.contesting.com/mailman/listinfo/antennaware
|