To: | amps@contesting.com, amps-request@contesting.com |
---|---|
Subject: | Re: [Amps] Harbach SB-220 Soft Start Relay Part # or, replacement |
From: | Adrian <vk4tux@gmail.com> |
Date: | Sun, 6 Oct 2024 09:33:09 +1000 |
List-post: | <mailto:amps@contesting.com> |
From: Aleksandar Petkovic<vk6apk@bigpond.com> To: Mark Bitterlich<markbitterlich@embarqmail.com>, David Gow <6146guy@gmail.com> Cc:amps@contesting.com Subject: Re: [Amps] Harbach SB-220 Soft Start Relay Part # or replacement Message-ID:<987a865a-3a7f-4607-9ada-a13ee3f0a354@bigpond.com> Content-Type: text/plain; charset=UTF-8; format=flowed I believe that the winding resistance takes care of it. 73, Alek VK6APK No it is the transformer core material and design. Similar to neon sign current limiting transformers. The core gaps are used in magnetic shunt paths of a current limiting transformer to limit secondary current. 73 vk4tux _______________________________________________ Amps mailing list Amps@contesting.com http://lists.contesting.com/mailman/listinfo/amps |
<Prev in Thread] | Current Thread | [Next in Thread> |
---|---|---|
|
Previous by Date: | Re: [Amps] Harbach SB-220 Soft Start Relay Part # or replacement, Aleksandar Petkovic via Amps |
---|---|
Next by Date: | Re: [Amps] Harbach SB-220 Soft Start Relay Part # or, replacement, Aleksandar Petkovic via Amps |
Previous by Thread: | Re: [Amps] Harbach SB-220 Soft Start Relay Part # or, replacement, Adrian |
Next by Thread: | Re: [Amps] Harbach SB-220 Soft Start Relay Part # or, replacement, Aleksandar Petkovic via Amps |
Indexes: | [Date] [Thread] [Top] [All Lists] |