Content-Type: text/plain; charset=UTF-8; format=flowed
I believe that the winding resistance takes care of it.
73, Alek VK6APK
No it is the transformer core material and design. Similar to neon sign current
limiting transformers.
The core gaps are used in magnetic shunt paths of a current limiting
transformer to limit secondary current.