Pull it all out, as has been well documented there is no need for a soft
start mod for th SB-220, it is built into the transformer. You are only
protecting the switch and an outlet strip will do that.
On Fri, Oct 4, 2024 at 5:00 PM Alek Petkovic via Amps <amps@contesting.com>
wrote:
> Well done.
>
> 73, Alek VK6APK.
>
> On 5/10/2024 4:38 am, Larry Carpenter wrote:
> > I think I have narrowed my Harbach Soft Start module failure to a
> defective 48 vdc spdt relay. This in turn caused the failure of the ceramic
> 10 watt 20 ohm resistors. Does anyone know who makes this relay or the
> model number or a substitute that will fit on the Harbach board?
> >
>
> Thanks,
> >
>
> Larry Carpenter
> > _______________________________________________
> > Amps mailing list
> > Amps@contesting.com
> > http://lists.contesting.com/mailman/listinfo/amps
>
> _______________________________________________
> Amps mailing list
> Amps@contesting.com
> http://lists.contesting.com/mailman/listinfo/amps
>
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps
|