 Ceramic Vac tune and load caps  mounted vertically, both with right angle
drives below chassis.   Between the front panel and sub front panel, they
will both feed a sprocket assy, so the actual turns counters will be above
the chassis.  Multi-tech industries Model 90 bandswitch has been modified,
such that there is now 40 amp contacts on both sides of the single wafer.
Contacts on both sides to be strapped in parallel. There is a pair of
multiple pole rotor assy's, (aka progressively shorting type bandswitch).

Neither vac cap has to be padded on 160M.