Possible stupid question alert.  Why not measure filament current instead of 
voltage?  Then you do not have to worry about accounting for losses in the 
filament path or the position of the voltmeter connection?  Or is there too 
much variability in the current drawn from tube to tube to be useable?

Randy AB9GO

-----Original Message-----
From: Amps <amps-bounces@contesting.com> On Behalf Of jim.thom 
jim.thom@telus.net
Sent: Tuesday, June 7, 2022 12:59 PM
To: amps@contesting.com
Subject: [Amps] Measuring fil V

****WARNING: This email originated outside of UC Health**** DO NOT CLICK links 
or open attachments unless you recognize the sender and know the content is 
safe.

Be careful if using a 10 kw resistor hanging off each cathode lug on a GG 
triode.
That might work if using a true rms dvm..since the dvm has a high Z input.

But if fed to an iron vane type of panel meter, you will end up with a massive 
V drop across both resistors.

A pair of  low  dc resistance chokes, bypassed at cold ends to chassis, is dead 
simple.  Then another pair of bypass caps at panel mounted test jacks.

Years ago, energy onix used RF chokes on one of it's  FM GG triode amps..and 
the dc resistance across the chokes was too high..and resulted in a vdrop.  
When the fil V was tweaked for  'normal' under load, using their front panel 
iron vane meter, the actual V at the cathode was way too high.
 This resulted in several premature tube failures.   And if a dvm was in
parallel  with the panel meter, it too will read on the low side.

Jim  VE7RF
_______________________________________________
Amps mailing list
Amps@contesting.com
https://urldefense.com/v3/__http://lists.contesting.com/mailman/listinfo/amps__;!!Ga0q2A!nWc6ZgAC4umYYcP_tIIdTr5OHrFfCqy03gKG8b4Lqd7-uMSj0R9m55UDT21pmVeKjd1BBPBH9nl4SiEQYg$

________________________________

Confidentiality Notice: This e-mail message, including any attachments, is for 
the sole use of the intended recipient(s) and may contain confidential and 
privileged information. Any unauthorized review, use, disclosure or 
distribution is prohibited. If you are not the intended recipient, please 
contact the sender by reply e-mail and destroy all copies of the original 
message.
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps

<Prev in Thread] Current Thread [Next in Thread>