Amps
[Top] [All Lists]

Re: [Amps] Amps Digest, Vol 217, Issue 1

To: amps@contesting.com
Subject: Re: [Amps] Amps Digest, Vol 217, Issue 1
From: Gary Smith <wa6fgi@steeltrails.net>
Date: Tue, 5 Jan 2021 12:05:44 -0800
List-post: <mailto:amps@contesting.com>
I too have a AL-82 have roughly the same current readings +- a few, Wavenode watt meter shows 1200-1300 Po.

Great old fashioned amp my grandson can use if he becomes a ham.

They are the kind of amp you can make a tuning mistake (keep it small one) and it will forgive you. Not so with SS amps unless they have a antenna tuner in them.

73,

Gary...wa6fgi

On 1/5/2021 9:00 AM, amps-request@contesting.com wrote:
Send Amps mailing list submissions to
        amps@contesting.com

To subscribe or unsubscribe via the World Wide Web, visit
        http://lists.contesting.com/mailman/listinfo/amps
or, via email, send a message with subject or body 'help' to
        amps-request@contesting.com

You can reach the person managing the list at
        amps-owner@contesting.com

When replying, please edit your Subject line so it is more specific
than "Re: Contents of Amps digest..."


Today's Topics:

    1. RPC 3-500 tubes (Robert Wood, P.E. (retired))
    2. Re: RPC 3-500 tubes (Jim)
    3. Re: RPC 3-500 tubes (Peter Voelpel)


----------------------------------------------------------------------

Message: 1
Date: Mon, 4 Jan 2021 17:01:00 -0600
From: "Robert Wood, P.E. \(retired\)" <woodr90@gmail.com>
To: <Amps@contesting.com>
Subject: [Amps] RPC 3-500 tubes
Message-ID: <00a401d6e2ed$78d28f40$6a77adc0$@gmail.com>
Content-Type: text/plain;       charset="us-ascii"

Recently purchased set of 3-500 tubes Made PRC and installed in AL82 amp

This AL82 had the Zener diodes replaced with diode string before I purchased
it YEARS ago.

Old arrl handbook shows 3-500 (single tube) with 30 watts input (GG-class B)
with 110 ma grid current.

My AL82 shows about 100ma grid current, two tubes, 80 watts out on driver
rig and about 1KW out.

Anyone else running set of Chinese 3-500 and could share grid current
readings?

and yes this is all issue because can't get power out

73 W5AJ

Robert

Midland, Texas



------------------------------

Message: 2
Date: Mon, 4 Jan 2021 17:24:55 -0600
From: Jim <jimw7ry@gmail.com>
To: amps@contesting.com
Subject: Re: [Amps] RPC 3-500 tubes
Message-ID: <c76eebdf-4471-7a0d-fec0-3cfb229f9ae7@gmail.com>
Content-Type: text/plain; charset=utf-8; format=flowed

I would try one tube at a time with 25 or 30 watts of drive. See if you
have a dead tube.



Thanks
73
Jim W7RY

On 1/4/2021 5:01 PM, Robert Wood, P.E. (retired) wrote:
Recently purchased set of 3-500 tubes Made PRC and installed in AL82 amp

This AL82 had the Zener diodes replaced with diode string before I purchased
it YEARS ago.

Old arrl handbook shows 3-500 (single tube) with 30 watts input (GG-class B)
with 110 ma grid current.

My AL82 shows about 100ma grid current, two tubes, 80 watts out on driver
rig and about 1KW out.

Anyone else running set of Chinese 3-500 and could share grid current
readings?

and yes this is all issue because can't get power out

73 W5AJ

Robert

Midland, Texas

_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps


------------------------------

Message: 3
Date: Tue, 5 Jan 2021 00:56:55 +0100
From: "Peter Voelpel" <dj7ww@t-online.de>
To: "'Robert Wood, P.E. \(retired\)'" <woodr90@gmail.com>,
        <Amps@contesting.com>
Subject: Re: [Amps] RPC 3-500 tubes
Message-ID: <86853CCDEE564EC69C5F0B0949B7CBDF@DJ7WWPC1>
Content-Type: text/plain;       charset="us-ascii"

For more power you will need more drive.

73
Peter

-----Original Message-----
From: Amps [mailto:amps-bounces@contesting.com] On Behalf Of Robert Wood,
P.E. (retired)
Sent: Dienstag, 5. Januar 2021 00:01
To: Amps@contesting.com
Subject: [Amps] RPC 3-500 tubes

Recently purchased set of 3-500 tubes Made PRC and installed in AL82 amp

This AL82 had the Zener diodes replaced with diode string before I purchased
it YEARS ago.

Old arrl handbook shows 3-500 (single tube) with 30 watts input (GG-class B)
with 110 ma grid current.

My AL82 shows about 100ma grid current, two tubes, 80 watts out on driver
rig and about 1KW out.

Anyone else running set of Chinese 3-500 and could share grid current
readings?

and yes this is all issue because can't get power out

73 W5AJ

Robert

Midland, Texas

_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps



------------------------------

Subject: Digest Footer

_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps


------------------------------

End of Amps Digest, Vol 217, Issue 1
************************************
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps

<Prev in Thread] Current Thread [Next in Thread>