I have a 1.5K-FA SPE here. Great amp, however getting any tech info out
of SPE is like getting blood out of a stone.
There is a tech doc for the 1KFA which seems the only tech info ever
released from SPE ;
http://vk4tux.duckdns.org/15KFA/Expert_Schematic_diagramsII.pdf
That may be useful as they are all very similar in design.
On 15/7/20 11:10 pm, Martin Sole wrote:
Hi,
I am looking at an SPE-2K for a friend. When checked last week the amp
appeared to function mostly okay but would not amplify. Metering
indication was no high voltage supply. Having bought the amp to my QTH
I have examined it in more detail. On opening the high voltage supply,
a MeanWell RSP 3000-48, 48 volt 62.5 amp, I found 3 dead and decaying
geckos, native to these parts and quite prolific.Having removed them
and any remaining detritus I switched on the amplifier and find the
supply gives the green OK when the amp is selected however the supply
voltage measures 34.9 volts instead of 48, confirmed with front panel
and fluke across the terminals. A small heat-sink in the power supply
that has four FET's and one TO200 diode mounted on it is rapidly heating.
Any thoughts on a possible cause?
I have not been successful in sourcing much information on this supply
other than a general data-sheet, certainly no schematics, though its a
switch mode power supply so...
Any more info out there?
Martin, HS0ZED
_______________________________________________