Amps
[Top] [All Lists]

[Amps] Low efficiency on 160 m

To: "amps@contesting.com" <amps@contesting.com>
Subject: [Amps] Low efficiency on 160 m
From: Markku Oksanen <ww1c@outlook.com>
Date: Sun, 15 Dec 2019 10:32:36 +0000
List-post: <mailto:amps@contesting.com>
All

I have a GU-78 amplifier based on the Russian R-140 military station.
It turns out that the efficiency is low on 160 m and I suspect that the tank 
circuit Q is low on 160 m.
However I am not sure if this is the cause.  The tank circuit Q is not high, 
that I can tell from the capacitor values.

Another symptom of non-optimal loading is that the screen current is negative 
unless I really push the drive to very high output and very close to having 
grid current.

I have tried to look for information about low Q tank circuit problems but no 
luck so far.

Markku
OH2RA/OG2A/WW1C