I've hipotted a lot of 213.  Never seen any leakage at 15KV DC which is the max on my.  If you put 259 on them, the BDV is around 4500 V though.

The weak spot on this sort of cable is not the cable itself but rather the connectors.  I used HV silicon wire which is good for some fantastic amount (40KV or something) but the best HV connector I could find was a very mechanically light-weight SHV (?) thing which i'm sure would break if you whacked it a bit.

Good luck Jim.

73/jeff/ac0c
alpha-charlie-zero-charlie
www.ac0c.com

On 5/13/19 9:10 AM, Steve wrote:
Indeed, other brands give the same number. I wonder if they all measure exactly the same result?

If you search for voltage breakdown figures for the polyethelyene dielectric you'll find numbers from 18kV/mm (450V/mil) going upwards. RG213 has dielectric 2.5mm/100mil thick.

OK, these are numbers for large flat surfaces at sea level with no humidity etc., and coax has an inner with curvature (although far short of a sharp point) but even so I think there's a lot of headroom above a 5kV figure.

Steve

On 13/05/2019 14:10, Joe wrote:
Interesting,

I was curious on this also, so Googled it and Pasternack has a datasheet for RG-213U
and it says it is only 5K

Max. Operating Voltage(VRMS): 5000
https://www.pasternack.com/images/ProductPDF/RG213-U.pdf

Joe WB9SBD

On 5/12/2019 12:13 PM, Steve Thompson wrote:
I think 213 will take that easily. It was a while ago, but I'm sure that I couldn't detect any leakage on 213 with my tester maxed out at 16kV. A local 'maker' group used it to repair a 35kV lead on a laser cutter. As far as I know it's working ok.

Good quality RG58 should take 8kV without any problems - again, I've had it at the limit of my tester. I suspect the cable working voltage specs are often derived from connector limitations.

Steve


Does anybody know how much max V is on RG-213 ?   Like what are the results if a hi-pot tester used.. and say cranked up to the point where  just a few microamps occurs .     I have an application where I need a  HV cable, less than 10 ft, that will  easily handle 5700 / 7700 vdc. It will be hardwired at both ends, no HV connectors. And with braid peeled way back from the center conductor, like  2-4 inches .  The plan was to also wrap some red electrical tape every few inches along its  entire length, to readily identify it as a HV cable.

Tnx....  JIm   VE7RF

_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps




_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps

_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps

<Prev in Thread] Current Thread [Next in Thread>