Amps
[Top] [All Lists]

Re: [Amps] SSR in amp PS not working as expected

To: Ulf Tjerneld <ulf@sm0nor.com>
Subject: Re: [Amps] SSR in amp PS not working as expected
From: Manfred Mornhinweg <manfred@ludens.cl>
Date: Wed, 09 Jan 2019 20:51:49 +0000
List-post: <mailto:amps@contesting.com>
I mistyped. The correct marking is Crydom CSD2425P. There are data sheets.

I see. Now I got the datasheet, and indeed you have the wrong kind of SSR. It's a zero-crossing triggering one, AND snubberless. If you had gotten the -10 version (CSD2425P-10), which is instant-triggering, it would probably work. And if you got one that also has a snubber, or else if you add a snubber, the chances for correct operation with inductive loads will increase.

Note that the datasheet, which is for several variants, even spells out that the zero-crossing triggering versions are for resistive loads, and the "random fire" (I prefer the term "instant triggering") versions are for inductive loads.

Manfred

========================
Visit my hobby homepage!
http://ludens.cl
========================