  Do you know anyone that has had first hand experience in running 4CX5000 
tubes in conventional grounded grid configuration? I have some that I would 
like to try perhaps. They have 75Watt control grid dissipation and 250 Watt 
screen grid dissipation.

  73

Bill wa4lav


________________________________
From: Amps <amps-bounces@contesting.com> on behalf of Jim Thomson 
<jim.thom@telus.net>
Sent: Tuesday, October 30, 2018 12:27 PM
To: amps@contesting.com
Subject: [Amps] Super Cathode Driven Tetrodes

Date: Sun, 28 Oct 2018 23:46:21 +0000
From: "Fuqua, William" <wlfuqu00@uky.edu>
To: Carl <km1h@jeremy.qozzy.com>, Jim Thomson <jim.thom@telus.net>,
"amps@contesting.com" <amps@contesting.com>
Subject: Re: [Amps] Super Cathode Driven Tetrodes

<Ok,

  <  Now that this discussion has gone on for some time, and everyone has had a 
opportunity to read various articles, here is the question.

<Can anyone give me a reason why a cathode driven tetrode with the control grid 
connected directly to

<the cathode be unstable. The screen grid is connected directly to ground. Low 
mu grounded grid configuration.


<73

<Bill wa4lav

##  Its  rock stable, based on data  from the 70s, from nearby hams who used 
that config.    But that was a 4CX-1000
in both cases.   160 w of drive for  1200 w pep out on ssb / cw..... =  power 
gain of just  7.5..... =  8.75 db.
The  super cathode driven config  was only used on tubes that had virtually no 
control grid dissipation, like 4CX-1000, and  4CX-1500B  etc.
Tubes like  4CX-5000, and bigger, can have both their control grid and screen  
grid bonded to chassis.. and run like a high mu triode.... just like a 4-400,
or  4-1000.

Jim   VE7RF

_______________________________________________
Amps mailing list
Amps@contesting.com
https://na01.safelinks.protection.outlook.com/?url=http%3A%2F%2Flists.contesting.com%2Fmailman%2Flistinfo%2Famps&amp;data=02%7C01%7Cwlfuqu00%40uky.edu%7C574466cf5e074ac0cccd08d63f39e48f%7C2b30530b69b64457b818481cb53d42ae%7C0%7C0%7C636765915209174411&amp;sdata=1Ouk3%2FRp6acLh%2B4ybrDikt%2F%2FkVpbu6wDyQXzm044cpg%3D&amp;reserved=0
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps

<Prev in Thread] Current Thread [Next in Thread>