To: | amps@contesting.com |
---|---|
Subject: | Re: [Amps] Plate Choke Issue |
From: | Steve Wright <stevewrightnz@gmail.com> |
Date: | Thu, 4 Jan 2018 07:21:37 +1300 |
List-post: | <mailto:amps@contesting.com> |
On 04/01/18 04:28, AJ wrote: > This time I was able to measure where it blew apart, ~20 uh from end to > end. I slid the wire off the broken ceramic and slid it onto a new one > mounted it in the amp to measure. I am referring to RFC-1 Well, 20uH in series with the tubes output capacitance is resonant on about 6-8 MHz. That might be worth exploring.. S _______________________________________________ Amps mailing list Amps@contesting.com http://lists.contesting.com/mailman/listinfo/amps |
<Prev in Thread] | Current Thread | [Next in Thread> |
---|---|---|
|
Previous by Date: | [Amps] Plate Choke Issue, AJ |
---|---|
Next by Date: | Re: [Amps] Plate Choke Issue (AJ), Chris Hays |
Previous by Thread: | [Amps] Plate Choke Issue, AJ |
Next by Thread: | Re: [Amps] Plate Choke Issue, Victor Rosenthal 4X6GP |