Amps
[Top] [All Lists]

Re: [Amps] SB220 step start blows fuses

To: <amps@contesting.com>
Subject: Re: [Amps] SB220 step start blows fuses
From: Catherine James <catherine.james@att.net>
Reply-to: Catherine James <catherine.james@att.net>
Date: Mon, 26 Jun 2017 12:28:59 +0000 (UTC)
List-post: <mailto:amps@contesting.com>
Any time the fan doesn't start immediately after power-up, shut down your 
SB-220 **immediately**.  You may have a short, and if the breakers/fuses don't 
blow, you will smoke the power supply very quickly.

73,
Cathy
N5WVR

--------------------------------------------
On Mon, 6/26/17, Warren Volz <warren@warrenvolz.com> wrote:

 Subject: [Amps] SB220 step start blows fuses
 To: amps@contesting.com
 Date: Monday, June 26, 2017, 1:54 AM
 
 All,
 
 I’ve been restoring a SB220 and
 finally got to the testing stage this weekend. When I turned
 it on, the HV went up to ~1kV and then started to drop.
 Successive cycles of the power switch did nothing. Oddly,
 the meter lights and fan never started running. I looked at
 the bottom of the amp tonight and the 3A fuses I added to
 the W7RY step start board blew. What areas should I look at
 now to determine what is going wrong? I have both tubes in,
 and I believe I previously checked them for filament shorts.
 I’m worried the HV supply has an issue.
 
 Any advice would be very much
 appreciated!
 
 Thanks!
 
 -Warren
 KD5YPH
 _______________________________________________
 Amps mailing list
 Amps@contesting.com
 http://lists.contesting.com/mailman/listinfo/amps
 
_______________________________________________
Amps mailing list