The 87A uses 3CX800A7 triodes.

It's my opinion that the Tl-922 suffers from an inferior power supply design. The 87A is vulnerable to PIN Diode burn out and the 3CX800A triodes can't stand any mistuning mistakes. A pair of 3-500ZG's will take 100 Watts of drive and about 3500V dc on the plates to hit the US legal limit. An un- modified TL922 won't do that. The 87A will do it with 50 Watts or less of drive but you better watch the grid current.

You can replace a pair of 3-500ZG's three times for the cost of one 3CX800A7.

On 9/24/2016 12:48 PM, jeanpierre.behiels@engie.com wrote:
Hi members;

Is there a real power output difference between a old Kenwood TL922 amplifier 
and a Alpha 87A automatic tune amplifer.
I now the TL922 use 3-500Z graphite tubes as finals,and the Alpha 87A 4CX800 
finals I think ?
Witch type of amplifier receive your preference .... ?



Regards Jean ON4AEF.




ENGIE Mail Disclaimer: http://www.engie.com/disclaimer/disclaimer-fr.html
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps


--
R. Kevin Stover
AC0H
ARRL
FISTS #11993
SKCC #215
NAQCC #3441


---
This email has been checked for viruses by Avast antivirus software.
https://www.avast.com/antivirus

_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps

<Prev in Thread] Current Thread [Next in Thread>