Those look good, but are no longer a stock item @ Mouser.
Looks like 90 minimum, with a 10-week lead time.
Thanks es 73,
Jim N7XCI
On 10/9/2013 11:29 PM, Jim Thomson wrote:
 
Date: Wed, 09 Oct 2013 17:57:23 -0700
From: Jim Barber <audioguy@q.com>
To: "Amps@contesting.com" <Amps@contesting.com>
Subject: [Amps] Alpha PA-76A bleeder/equalizer resistors
I'm working on a PA-76A, doing the obvious stuff - replacing the filter
caps, the tantulum timing cap, the low-voltage filter etc. All well and
good.
What raised my question is the bleeder/equalizer resistors across the HV
filter caps. Apparently stock, each cap has two 120K 2-watt carbon comp
resistors across it in parallel. With 2400V B+, that looks like 60K ohms
across 400V, or ~ 2.7 watts per 4-watt pair. All the resistors are
either open or close to it, interestingly enough.
First, I looked at a few posted images on the internet. Yep, it looks
like that's what Alpha used, although the schematic I have says each
"unit" should have 220K @ 2 watts across it...
So: Inquiring minds would like to know what to use to replace them?
I'm thinking maybe 2 220K Ohmite OY (in parallel of course) across
each? That would lower the bleeder current, but I'm not seeing a huge
problem with that at first glance. ?
For whatever its worth, the original problem with the amp was that there
was substantial 120hz hum modulation on the output signal.
Since this is an original two-holer, I'm hoping the problem is strictly
in the B+ supply since a cathode-filament short in one of the 3CX400's
would mean either a retrofit or something equally undesirable...
Tnx es 73,
Jim N7CXI
##  forget the carbon comp crap..and ditto with a pair of 220k Ohmite OY.
##  use a single 100k, 3 watt MOF resistor  across each lytic.
## VISHAY  1% TOL.
##   PN- 3  100K  1% T – 2 B14
SAP  PN: CPF3100K00FHB14
##  Stock item  from MOUSER.  Mine came in boxes of 100.  I measured all
300 of em from 3 x boxes...and there is only 20 ohms at most between any of 
them.
That equates  to .2 % Tolerance.   Great, no more mucking about trying to  play 
matchup.
The late Tony W4ZT  put  me onto these beauties.   The actual value is not 
critical.  Anything
from 90-110 k  is fine.  What is critical is that they are all the same, or 
very close in value.
With these Vishay resistors, the V drop across each lytic is identical !
later......... Jim  VE7RF