Thanks Carl,
can you tell me more, what is wrong with his methods (I know he gets too 
religious, but knows his technical stuff too). I talked with him some 10 
years ago, he might have changed a bit by now. 
I did not understand what you meant by "use the generic brute force method".
Karel
VA3KO
----- Original Message ----- 
From: "Carl" <km1h@jeremy.mv.com>
To: "Karel Ebenstreit" <kebenstr@bmts.com>; <jim.thom@telus.net>; 
<amps@contesting.com> 
Sent: Monday, June 03, 2013 9:34 PM
Subject: Re: [Amps] SB200 on 6M
 
More like infamous. That is the voodoo crap I mentioned earlier.
Carl
KM1H
Subject: Fw: [Amps] SB200 on 6M
 
sorry forgot to cc.
Karel, VA3KO
----- Original Message ----- 
From: "Karel Ebenstreit" <kebenstr@bmts.com> 
To: "Louis Parascondola" <gudguyham@aol.com>
Sent: Monday, June 03, 2013 7:05 PM
Subject: Re: [Amps] SB200 on 6M
 Why do not  you use famous Richard Measure, he designs and sell 
suppressors for all makes.
I am not sure if he is still around, I used him for my 4-1000A's and 
3-500's. some time ago.
Karel , VA3KO
----- Original Message ----- 
From: "Louis Parascondola" <gudguyham@aol.com> 
To: <km1h@jeremy.mv.com>; <jim.thom@telus.net>; <amps@contesting.com>
Sent: Monday, June 03, 2013 6:57 PM
Subject: Re: [Amps] SB200 on 6M
 Knowing the right suppressor to use on an SB-200 conversion is what 
makes the bucks.
Having to use a high wattage resistor on such a small tube as a 572B 
means
you havent a clue about suppressor design, and simply use a generic 
brute 
force method.
Carl
KM1H
-----Original Message-----
From: Carl <km1h@jeremy.mv.com>
To: Jim Thomson <jim.thom@telus.net>; amps <amps@contesting.com>
Sent: Mon, Jun 3, 2013 5:56 pm
Subject: Re: [Amps] SB200 on 6M
 
I'm converting a SB200 for 6M. What's the best configuration for the
Anti-Parasitic Choke?
Thanks
- Paul
##  dunno.  BUT if the 2 watt carbon comp resistors heat up,  use more 
of 
em in parallel,
OR  use a small 7-10-15 watt  GLOBAR.    You can still buy the small
globars  with wire leads
out each end..still on their website.    Dunno what the min order is
though.
##  On several 4-1000  HF amps from years ago, we would use five  of 
those 
carbon comp resistors
in parallel...end of heating problems.
Jim  VE7RF
 
Having to use a high wattage resistor on such a small tube as a 572B 
means
you havent a clue about suppressor design, and simply use a generic 
brute 
force method.
Carl
KM1H
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps
 
 
-----
No virus found in this message.
Checked by AVG - www.avg.com
Version: 10.0.1432 / Virus Database: 3184/5880 - Release Date: 06/03/13
 
 
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps
 |