Yes they are.
On 3/7/2013 9:58 AM, Carl wrote:
 
Is the ARRL still using a 6dB fudge with the way they measure IMD?
Carl
KM1H
----- Original Message ----- From: "Paul Christensen" <w9ac@arrl.net>
To: <amps@contesting.com>
Sent: Thursday, March 07, 2013 8:06 AM
Subject: Re: [Amps] Expert 1k amp
 
Steve,
I did an unscientific check with my SPE 1K.  Ripple on the RF 
envelope at the 1KW level is no worse than with my Alpha 77Dx and 87A 
at 1500W.  It's just noticeable on the scope at the maximum power 
level.   Yes, total drain current is about 40-42 amps. 
If the QST Product Review is any indication of the amp's IMD 
performance, 3rd-order 2-tone is about -40 dBc.  Not sure how well 
that figure holds up across a sample of units.  The IMD spectra of 
the 2K model appears very close.  Apart from fault detection and T/R, 
I've not spent much time with the rest of the schematic so it would 
be interesting to see how they achieve reasonably good IMD at full 
power that's competitive with many VT amps. 
These are not "brick-on-the-key" amps.  In the case of the 1K, the 
software automatically cuts back power to 50% after about 15 
seconds.  I don't run high duty-cycle modes like RTTY, but I think it 
would be a painful experience in a contest between automatic power 
reduction and fan noise. For me, it's a good instant-on alternative 
for my operating modes, but it would not be my only amp. 
Paul, W9AC
----- Original Message ----- From: "Steve Thompson" <g8gsq72@gmail.com>
To: <amps@contesting.com>
Sent: Thursday, March 07, 2013 3:50 AM
Subject: [Amps] Expert 1k amp
 Yesterday I did some minor repairs to a friend's amp - resoldering 
joints on the current sensing resistor. Looking at the circuits 
later I noticed that the main supply voltage is regulated by having 
SCRs in place of diodes rectifying the transformer secondary and the 
main smoothing capacitor is 47000uF.
My friend tells me the amp runs over 40A at full tilt, which means 
something like 8.5V ripple on the supply (7V at 60Hz). That strikes 
me as quite high and I'd expect to see some difference in amplifier 
gain/output if I was running such an amp off a regulated supply and 
altered the voltage that much. Has anyone measured one? Is any 
100/120Hz audible on a carrier? 
Steve
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps
 
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps
-----
No virus found in this message.
Checked by AVG - www.avg.com
Version: 10.0.1430 / Virus Database: 2641/5652 - Release Date: 03/06/13
 
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps
 
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps
 |