Amps
[Top] [All Lists]

Re: [Amps] 3CX1500A7/8877 vs el cheapo GS-35B

To: <amps@contesting.com>
Subject: Re: [Amps] 3CX1500A7/8877 vs el cheapo GS-35B
From: MIKE DURKIN <patriot121@msn.com>
Date: Tue, 31 Jul 2012 11:41:59 -0700
List-post: <amps@contesting.com">mailto:amps@contesting.com>
Well shoot .... I hit 94cfm ... and yea, its noisy. Im sure the fan noise is 
lower at 83cfm...

> From: km1h@jeremy.mv.com
> To: dezrat1242@yahoo.com; amps@contesting.com
> Date: Tue, 31 Jul 2012 14:14:41 -0400
> Subject: Re: [Amps] 3CX1500A7/8877 vs el cheapo GS-35B
> 
>             Physical Characteristics
>             Envelope  metal-ceramic
>             Cooling  forced air
>             Minimum required Air flow  2500 l/min (83.3 cfm)**
>             Diameter  100.2 mm max
>             Length  min 173 max 177mm (6.9")
>             Anode Diameter  min 99.7 max 100.2 mm (4")
>             Grid diameter min 59.5 max 60.3 mm
>             Cathode  indirectly heated, oxide coated
>             Cathode Diameter min 40 max 40.5 mm
>             Heater Diameter min 25.6 max 26.2 mm
>             Weight including copper heatsink 2.8Kg (6.17 lbs)
> 
>       **Commonly published data shows 1500 liters/min as 90 cfm but that 
> conversion is WRONG. The correct data is 2500 liters/min or 150 cubic meters 
> per hour which is 83.3 cubic feet per minute. 90 cfm is still a good target 
> number.
> 
> 
> 
> 
> ----- Original Message ----- 
> From: "Bill, W6WRT" <dezrat1242@yahoo.com>
> To: "AMPS" <amps@contesting.com>
> Sent: Tuesday, July 31, 2012 12:34 PM
> Subject: Re: [Amps] 3CX1500A7/8877 vs el cheapo GS-35B
> 
> 
> > ORIGINAL MESSAGE:
> > On Tue, 31 Jul 2012 06:43:47 -0400, Carl wrote:
> >
> >>. I wouldnt want to be in the same room with the blower for one or two
> >>GS-35B's.
> >
> > REPLY:
> > I noticed the specs for the GS-35b don't specify a recommended CFM for 
> > cooling
> > but they do say the maximum temp for cathode and grid leads is only 120 
> > degrees
> > C. That's pretty low compared to many tubes. A 3-500Z for example is rated 
> > at
> > 200 C for those same leads.
> >
> > A builder would be wise to check temps with color-changing crayons or 
> > paint.
> >
> > 73, Bill W6WRT
> >
> >
> > _______________________________________________
> > Amps mailing list
> > Amps@contesting.com
> > http://lists.contesting.com/mailman/listinfo/amps
> >
> >
> > -----
> > No virus found in this message.
> > Checked by AVG - www.avg.com
> > Version: 10.0.1424 / Virus Database: 2437/5166 - Release Date: 07/30/12
> > 
> 
> _______________________________________________
> Amps mailing list
> Amps@contesting.com
> http://lists.contesting.com/mailman/listinfo/amps
                                          
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps

<Prev in Thread] Current Thread [Next in Thread>