Its the current thats more important and the suitability of the cap for the
frequency.
I use a 5KV RF doorknob for up to around 3500V and up to 1200W or so on 6M.
For 2X power I double or triple them in parallel.
The standard HEC HH58 type 5KV and 7.5KV doorknob is the same and just have
different headroom.
For serious voltage and RF I use the HT-57 size.
Carl
KM1H
----- Original Message -----
From: <mikflathead@aol.com>
To: <amps@contesting.com>
Sent: Friday, April 06, 2012 5:33 PM
Subject: [Amps] Plate blocking cap voltage
> What is the rule of thumb for the plate blocking cap voltage? 2 times high
> voltage, 3 times high voltage? This will be for a 4-1000 for 6 meters.
> Thanks Mike
> _______________________________________________
> Amps mailing list
> Amps@contesting.com
> http://lists.contesting.com/mailman/listinfo/amps
>
>
> -----
> No virus found in this message.
> Checked by AVG - www.avg.com
> Version: 10.0.1424 / Virus Database: 2409/4918 - Release Date: 04/06/12
>
_______________________________________________
Amps mailing list
Amps@contesting.com