Hi, 

I'm thinking about ACOM 1010 6m conversion, did anyone done
that? 

I think it using pasiv grid design, so at leats I will have to
change: 

- input circuit to extend coverage to 50MHz (to neutralize to
tube input capacitence also at 50 MHz), 

- check plate choke for
resonance at 6 m band, 

- use smaller section of tune capacitor
(possible to be swithed with vacuum relay) 

- add aditional switch
(perhaps at rear side) for switching vacuum relays (for swithing band
switch, smaller section of tune capacitor and tube input compensation
circuit). 

- find tap at PI and L coils, 

vy 73, Branko, S52V 

  