| To: | amps <amps@contesting.com> |
|---|---|
| Subject: | Re: [Amps] DIODE PIV Confusion |
| From: | Ron Youvan <ka4inm@tampabay.rr.com> |
| Reply-to: | ka4inm@tampabay.rr.com |
| Date: | Wed, 29 Jun 2011 14:03:09 -0400 |
| List-post: | <amps@contesting.com">mailto:amps@contesting.com> |
Jim Forsyth wrote:
> How would you measure the PIV?
You can measure the breakdown Voltage with a scope, ac power supply and a
resistor.
The "PIV RATING" is a breakdown Voltage that their products shall not fall
below.
40 years ago I measured many 1N4001's (50 Volt at 1 Amp.) and most broke down
around 155 Volts.
--
Ron KA4INM - A city is a large community where people
are lonesome together -- Herbert Prochnow
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps
|