To: | amps <amps@contesting.com> |
---|---|
Subject: | Re: [Amps] DIODE PIV Confusion |
From: | Ron Youvan <ka4inm@tampabay.rr.com> |
Reply-to: | ka4inm@tampabay.rr.com |
Date: | Wed, 29 Jun 2011 14:03:09 -0400 |
List-post: | <amps@contesting.com">mailto:amps@contesting.com> |
Jim Forsyth wrote: > How would you measure the PIV? You can measure the breakdown Voltage with a scope, ac power supply and a resistor. The "PIV RATING" is a breakdown Voltage that their products shall not fall below. 40 years ago I measured many 1N4001's (50 Volt at 1 Amp.) and most broke down around 155 Volts. -- Ron KA4INM - A city is a large community where people are lonesome together -- Herbert Prochnow _______________________________________________ Amps mailing list Amps@contesting.com http://lists.contesting.com/mailman/listinfo/amps |
<Prev in Thread] | Current Thread | [Next in Thread> |
---|---|---|
|
Previous by Date: | Re: [Amps] DIODE PIV Confusion, Steve Katz |
---|---|
Next by Date: | Re: [Amps] DIODE PIV Confusion, Dr. David Kirkby |
Previous by Thread: | Re: [Amps] DIODE PIV Confusion, Jim Forsyth |
Next by Thread: | Re: [Amps] DIODE PIV Confusion, Dr. David Kirkby |
Indexes: | [Date] [Thread] [Top] [All Lists] |