You have a shorted tube.
  ----- Original Message ----- 
  From: ED MCKIE 
  To: amps@contesting.com 
  Sent: Thursday, May 26, 2011 6:18 PM
  Subject: [Amps] Henry 2KD-5 Problem


  Last night I was using my 2KD-5, and it was working fine. After making
  several transmissions with no problem, it made a loud pop when keyed. Now
  the grid current indication goes off scale in the negative direction as soon
  as it is turned on, and stays there even with drive applied. It also has
  plate current flowing ( about 300 mA ) even when not keyed. It is still
  working and has output.
   I have to get someone to move it to my workbench due to a back injury, so
  all I've done so far is to remove the top. The bias diode reads 13.5 Kohm in
  both directions when checked with one end of the 220 Ohm parallel resistor
  lifted, but I see nothing that made the loud pop, so far.
   When I get it on the bench I can get into it, but wondered if anyone else
  had seen these problems in this or a similar amplifier.
  Thanks & 73,
  Ed,  KB5GT
  _______________________________________________
  Amps mailing list
  Amps@contesting.com
  http://lists.contesting.com/mailman/listinfo/amps


  -----
  No virus found in this message.
  Checked by AVG - www.avg.com
  Version: 10.0.1375 / Virus Database: 1509/3660 - Release Date: 05/25/11
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps

<Prev in Thread] Current Thread [Next in Thread>