2 MW out with 26 kV x 110 Amps (plus 60 kw of drive feedthru due to
cathode driven) is quite good efficiency, 68%.
180 kW is the average (equivalent CW) power, as it is a pulsed
amplifier. The peak power needs high peak voltage. The high average
power needs a lot of DC current and makes heat. Both regimes are tested.
No new photos online besides the 3 technical papers I posted links to, a
month ago.
John
K5PRO
> Message: 4
> Date: Fri, 13 May 2011 23:39:27 -0500
> From: donroden@hiwaay.net
> Subject: Re: [Amps] testing a big amp
> To: amps@contesting.com
> Message-ID: <20110513233927.46323sjdejn20xhb@webmail.hiwaay.net>
> Content-Type: text/plain; charset=ISO-8859-1; DelSp="Yes";
> format="flowed"
>
> One Hundred and Ten Amps ??
>
> Not very efficient @ 180KW load.
>
> Two point eight megawatts in / 180 KW out
>
> Don W4DNR
>
_______________________________________________