Amps
[Top] [All Lists]

Re: [Amps] Plate load impedence

To: amps@contesting.com
Subject: Re: [Amps] Plate load impedence
From: Vic K2VCO <vic@rakefet.com>
Date: Sat, 03 Jul 2010 18:47:00 -0700
List-post: <amps@contesting.com">mailto:amps@contesting.com>
On 7/3/2010 5:06 PM, Barrie Smith wrote:
> Just recently there was a thread concerning the multiplication factor for 
> calculating
> plate load impedence.
>
> There was one post that indicated that the multiplication factor changed 
> relative to
> class of operation.
>
> 1.8 was mentioned for class AB1 (if I remember correctly), but what would the 
> factor be
> for AB2, B and C?

According to the G3SEK Pi/L design spreadsheet, the values are as follows:

Class A: 1.3    
Class AB: 1.5-1.7       
Class B: 1.57-1.8       
Class C: 2.0    
        

-- 
Vic, K2VCO
Fresno CA
http://www.qsl.net/k2vco/