Amps
[Top] [All Lists]

Re: [Amps] HV connector

To: jtml@vla.com
Subject: Re: [Amps] HV connector
From: K9FFK <k9ffk@comcast.net>
Reply-to: k9ffk@comcast.net
Date: Sat, 16 Jan 2010 14:12:10 -0600
List-post: <amps@contesting.com">mailto:amps@contesting.com>
John Lyles wrote:
> SHV, MHV all good. I thought I remember MHV being a 10 kV rating, but 
> maybe its another one. The only thing I dislike about these is that they 
> are mostly used on RG58/59 sized cables. If you want to really improve 
> your HV rating, use RG8 or one of the variants with solid polyethylene 
> dielectric. Then you may use a HN or SC connector. The HN is a heck of a 
> connector.
>
> _______________________________________________
> Amps mailing list
> Amps@contesting.com
> http://lists.contesting.com/mailman/listinfo/amps
>
>   
SHV connectors can be obtained in 5, 10, 20 kV ratings.
The SHV-20 connector series (20 kV rating) replaces an older SHV-15 type 
(15 kV).
Do not intermix the two series.
see << http://www.isi-seal.com/urd/uniface.urd/ecf0070w.display?9.2.9.1>>

MHV appears to be and has been rated at 5 kV only.

Dick K9FFK
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps