It could be a weak tube or some RF component drifting from heating.
Carl
KM1H
----- Original Message -----
From: "ka1mwp" <ka1mwp@comcast.net>
To: <Amps@contesting.com>
Sent: Thursday, June 11, 2009 6:33 PM
Subject: [Amps] screen grid current dropping
> Well, here is one I can't seem to figure out easily..
>
> My GU-84b amp with 2100v plate, -65 on control grid, 365v on screen
> grid, have a meter monitoring the
> Screen current.
>
> I watch this current go from .7ma idle to 25ma at 1kw key down..(can't
> do this long on the oil filled dummy load)
>
> The current drops from 20 or so ma down thru 12 with the voltages and
> output watts staying pretty close to values.
>
> I'm using the tetrode boards and have it setup as in the manual..only
> slight component value changes for the screen
> Resistors to get correct volts out, which is rock solid at 365vdc.
>
> Clues to look at?
>
> The schematic I posted on the site is pretty close to what I have.
>
>
> http://home.comcast.net/~ka1mwp/gu84b_new_sch_rev4.JPG
>
>
> thanks for any help in the search.
>
> Chuck
> _______________________________________________
> Amps mailing list
> Amps@contesting.com
> http://lists.contesting.com/mailman/listinfo/amps
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps
|