Bite the bullet and remove the transformer.
Cut the primary leads as long as possible.
Remove the 4 bolts, and carefully tip up, with care the HV leads stay
attached to the HV board. The lower one is a PITA to get at.
Mount a solder lug strip on the inside rear wall. You can use the strip
plus a few twist connectors to reattach everything.
Carl
KM1H
----- Original Message -----
From: "David H Walker" <davidhdhwalker@gmail.com>
To: <amps@contesting.com>
Sent: Saturday, March 28, 2009 2:18 PM
Subject: [Amps] Dentron 2500
> My favorite MLA 2500 has a bad power cord. For the live of me I cannot
> figure out the best method of changing the power cord. Everything is
> so
> close and I do not wish to disassemble the whole back if this is not
> needed.
> 73
> David
>
> --
> K0COP
> David H. Walker
> PO Box 2378
> Aiken, SC 29802
> Time=EDT
> FAX=803 648 2921
> _______________________________________________
> Amps mailing list
> Amps@contesting.com
> http://lists.contesting.com/mailman/listinfo/amps
_______________________________________________