Dan...
The input impedance of a transistor at RF frequencies runs a few ohms,
depending on a variety of factors, with high power meaning lower
impedance. 30 dB in power means 1000:1 in power or about 30:1 in
voltage. The network analyzer measures power in 50 Ohms, but if
connected to a source of only a few ohms, it basically becomes a voltage
measuring device. So, if the input matching network transforms 50 Ohms
down to 1.5 Ohms, that would result in the measuring a 30:1 voltage
reduction, about what you saw.
jeff, wa1hco
Dan Sawyer wrote:
> I have a couple solid state RF power amps to test. One question is: What
> is their bandpass? I connected a network analyser drive to the output
> and then took the NA input of the collectors. Accounting for the
> impedance mismatch, this worked quite well, the amps showed good
> bandpass characteristics across the 2 to 30 MHz HF range.
>
> I then connected the NA drive to the amps input and took the NA input at
> the transistor bases. This did not work at all, the NA showed close to a
> 30 db loss across the range. What am I missing here? It would seem there
> should be at lease a discernible signal characteristic by this method.
>
> Thanks - Dan
> _______________________________________________
> Amps mailing list
> Amps@contesting.com
> http://lists.contesting.com/mailman/listinfo/amps
>
>
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps
|