> For accuracy I definitely would use some 1% to 5% resistors in a 
> separate multiplier string.

Use considerably higher values in the multiplier string so that they 
don't act as bleeder resistors.  Using something like a 9 megohm 
resistor in series with a 1 megohm would give a 10:1 voltage ratio if 
the voltmeter has a high ohms per volt.  I know, this is not exact. 
But, close enough for government work.
>
> Most bleeder resistors don't have high tolerances so they can vary 
> quite a bit in relation to each other.

I guess you havent checked out 5-10W resistors in a LONG time. Many are 
rated at 5% tolerance and most measure withinn 2% thanks to modern 
manufacturing processes.

Your suggestion makes no sense unless money is no object....have you 
priced a 9M precision resistor rated at several KV?

If ultimate accuracy is desired on the cheap, buy extra bleeders, match 
to within 1% , then take the meter line off the top of the last cap in 
the string and finish the divider based on the meter sensitivity, this 
will require several megohms to complete. You are now at a relatively 
low voltage and can finish off with common 1/2W film resistors.The 
SB-220 used 14 M in the string.

Carl
KM1H


>
> Glen, K9STH
>
> Website:  http://k9sth.com
>
>
> --- On Wed, 12/17/08, Steve Flood <kk7uv@bresnan.net> wrote:
>
> From: Steve Flood <kk7uv@bresnan.net>
>
> Is it 'better' to meter the high voltage at the bottom of a bleeder 
> string (I have 8 100k resistors in a SB-220-style power supply), or is 
> it 'better' to build a seperate multiplier string between B+ and B- 
> for the meter?
>
>
>
> _______________________________________________
> Amps mailing list
> Amps@contesting.com
> http://lists.contesting.com/mailman/listinfo/amps
> 

_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps

<Prev in Thread] Current Thread [Next in Thread>