Amps
[Top] [All Lists]

Re: [Amps] Tl-922 plate meter protection

To: as1935@012.net.il,Amps@contesting.com
Subject: Re: [Amps] Tl-922 plate meter protection
From: Missouri Guy <n0tt1@juno.com>
Date: Wed, 23 Apr 2008 14:27:11 +0000
List-post: <amps@contesting.com">mailto:amps@contesting.com>
Aron,

A diode across the meter will usually work on sensitive
meters.   Connect the diode's cathode to the negative terminal
so it will conduct if the voltage across the meter (and
diode) exceeds about 0.6v.   Experiment to see which diode
works best with your particular meter and/or meter circuit.

73,
Charlie, N0TT


On Wed, 23 Apr 2008 15:33:15 +0300 slonim aron <as1935@012.net.il>
writes:
> Hi
> Wonder whats the best way to protect the plate meter against
> damage during "vhf parasitic".
> Thanks.
> Aron 4x1fq.
> _______________________________________________
> Amps mailing list
> Amps@contesting.com
> http://lists.contesting.com/mailman/listinfo/amps
> 
> 
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps

<Prev in Thread] Current Thread [Next in Thread>