>I am a newbee non technical novice. I bought a SB 220 .
>Changed the wiring according to the manual from 110 to 240.
>Plugged linear into a mfj soft start plug and blew a fuse
>in mfj box.( power off on linear whole time) . Inspected
>the linear and discovered that the interlocking spring was
>hitting the metal spacer mounted on the feedthrough
>insulator.?
If the power was off on the linear, as you say above, the
fuse blowing has NOTHING to do with the interlock. You must
have a wiring problem.
Before doing anything more measure the resistance from the
power cord pins to the chassis of the amplifier. It should
be infinite with the power switch off or on.
This is because all good designs do not connect any part of
the primary circuit to the chassis. :-)
You need to learn why the fuse blew with the amplifier off.
This is almost certainly a wiring issue, or perhaps an
unintentional short.
THEN, only after you fix that, it is time to worry or ask
about other things.....like the interlock.
73 Tom
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps
|