On 4 Jul 2007 at 7:03, Robert Groh wrote:
> Cleaning up the basement some more and preparing to sell off some 4-1000A RF
> decks. I am looking for some idea of what the power transformer output
> current specifications might be. The only information I have is:
> UTC Special Series Type S50
> Primary: 115V
> Secondary 1: 5 KV center tapped
> Secondary 2: 6 KV (no center tap)
> Size: Large! About 7-1/2" w x 9-1/4" deep x 10-1/2" tall
My UTC catalog (1963-1964 vintage) shows the S-50 as a "plate
transformer" with:
115VAC primary
3000-2500-0-2500-3000 secondary giving 2625 or 2175 VDC at 300mA dc.
so it appears that what called "secondary 2" is really the HV ends of
"secondary 1"
The case is "G-12" which is 10 1/4 " x 7 3/8" x 9 1/4" and it weighs
in at 52 lbs.
73,
George T. Daughters, K6GT