In a message dated 1/28/2007 2:52:27 PM Eastern Standard Time, 
dhallam@rapidsys.com writes:
Given the relative low accuracy of normal AC panel meters, how can you be
sure that you are actually within the filament voltage tolerance specified
by the manufacturer?  A high accuracy AC meter is a rather large and
somewhat expensive animal.

One way I have done it is to make my own AC panel voltmeter using a low ac ma 
range meter and variable resistor and calibrate it with a good quality AC RMS 
DVM like a Fluke. Likewise you can check the calibration of a regular AC 
voltmeter with a DVM. Then you should have a good accurate AC voltmeter 
calibrated 
to your target voltage.