About lowpass filters for a 1.5 kW transmitter: It might be advisable, IF you have the potential for TVI, to make a lowpass (or bandpass) filter for the transmitter and then follow it another filter which is especially designed to have zero lead-length in the shunt capacitors to ground. This will insure good stopband performance up in the 100 MHz region and above. A fine example of what I am talking about (with pictures!) is here: http://www.realhamradio.com/DC_54_mhz_lowpass_filter.htm - Jim WB6BLD _______________________________________________ Amps mailing list Amps@contesting.com http://lists.contesting.com/mailman/listinfo/amps |