R. Measures wrote: > >The 30S-1 is cathode-driven because no signal applied between the grid >and the cathode. > It is cathode-driven because the RF input is connected to the cathode - and nothing else (still looking at the schematic here). >> I could never see how a 4CX1000A could function well in a >> grounded grid mode. > >The screen grid is grounded Yes... >and the control grid is at the same signal potential as the cathode. The control grid and cathode are not connected in the 30S-1. G1 is essentially bypassed to ground. It receives a small fraction of the *anode* voltage as negative feedback, but it isn't connected to the cathode at all. -- 73 from Ian G/GM3SEK http://www.ifwtech.co.uk/g3sek _______________________________________________ Amps mailing list Amps@contesting.com http://lists.contesting.com/mailman/listinfo/amps |