On Oct 31, 2005, at 6:08 PM, Peter Chadwick wrote:

> How do you keep within the ICNIRP limits with high power? They suggest 
> a maximum field strength at HF where a piece of ungrounded metal could 
> be touched of 30volts/metre maximum. 60 volts/meter maximum if there's 
> no ungrounded metal around. I suspect even a 100 watt mobile exceeds 
> that in the near field at HF. The physiological effects worked on the 
> basis of the 6 minute integration period probably aren't an issue, 
> especially with the duty cycle of SSB or CW, but the induced voltage 
> from the antenna near field giving the capability of RF burns to 
> someone touching a bit of metal is another matter.

Would not this act as a deterrent to car jackers?
>
> 73
>
> Peter W6/G3RZP
> _______________________________________________
> Amps mailing list
> Amps@contesting.com
> http://lists.contesting.com/mailman/listinfo/amps
>
>

Richard L. Measures, AG6K, 805.386.3734.  www.somis.org