On Aug 12, 2005, at 9:14 AM, gdaught6@stanford.edu wrote:

> Hi all,
>
> While we're on the subject of soft/step start circuits, I'd like to
> ask a question that I've had for years, but never asked until now:
>
> Why do most step-start circuits in the primary of the HV transformer
> have tow resistors and relay contacts shorting the resistors in EACH
> (i.e. BOTH) leads of the primary?

So that it will work right on either 120v Or 240v mains.
>
> Doesn't a single resistor and relay do the same job?  It's a single
> current path.

In a 240v only amplifier, yes.
>