Amps
[Top] [All Lists]

[Amps] RE : Led display problem

To: "'Carcia, Francis A HS'" <francis.carcia@hs.utc.com>,"'Patrick EGLOFF'" <pegloff@gmail.com>, <amps@contesting.com>
Subject: [Amps] RE : Led display problem
From: "hermans" <on4kj@skynet.be>
Date: Tue, 19 Apr 2005 21:08:38 +0100
List-post: <mailto:amps@contesting.com>
Hall effect!!.... would you make clear how you would proceed with a hall
effect Francis. 

Jos on4kj

De?: amps-bounces@contesting.com [mailto:amps-bounces@contesting.com] De
la part de Carcia, Francis A HS
Envoyé?: mardi 19 avril 2005 14:31
À?: 'Patrick EGLOFF'; amps@contesting.com
Objet?: Re: [Amps] Led display problem

how about a hall effect sensor???

-----Original Message-----
From: Patrick EGLOFF [mailto:pegloff@gmail.com]
Sent: Monday, April 18, 2005 5:30 PM
To: amps@contesting.com
Subject: [Amps] Led display problem


Hi All,
I'm new on this list...

I'm planning to build a 2m amp with a 4CX1500B tetrode.
I want it a bit state of the art and replace the meters with LED bars.

My design will be a cathode driven, DC grounded amplifier and i want to 
monitor at least screen, grid and anode current and anode voltage.

The LM3914 input seems to be always referenced to ground. No problem to 
measure the screen current for which a pole of the supply is grounded.

But a bit more difficult to measure the other currents and voltages for 
which the reference et the cathode level.

Has anyone an idea how to do that, on a simple way ?

73, Patrick TK5EP.
http://tk5ep.free.fr
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps

_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps

<Prev in Thread] Current Thread [Next in Thread>