Dear Chris,
Some methods I employ in construction of amplifier metering
involve the use of ceramic disk bypass capacitors at both ends of
all control leads, everywhere.
Another method is to use a small Bud aluminum box around the meter
and in very hectic situations, employ tiny threaded feed-through
capacitors
for the leads into the boxes.
Hal Mandel
W4HBM
On Sat, 26 Mar 2005 12:48:48 -0800 "Chris" <rfcrazy@cox.net> writes:
> Hello to the group,
>
> I have a question in regards to rf getting into my filament meter. I
> put
> chokes on the leads to the meter to keep rf out, but its not coming
> into
> the meter thru the wires, it just stray rf from the deck. The meter
> is
> mounted on the face of the deck. Any suggestion how I may shield
> the
> meter or fix this?
>
> Chris