Not a variac Rich, that transformer quiz you had a while back about
surge current. Didn't it calculate to something over 100 amperes?
Will
On Sun, 30 Jan 2005 14:26:41 -0800, R. Measures <r@somis.org> wrote:
I have never measured the inrush-I to a Variac at startup.
On Jan 30, 2005, at 1:07 PM, Will Matney wrote:
Rich,
Yes, it sure will and is what it's designed to do. Another member on
here and myself done some investagating on surge currents and it was
surprising about how many cycles it takes for a transformer to
completely level out (about 20-25 if I remember on the one test). The
first few cycles (about six) was really when it drew the most and were
talking a HUGE amount. Richard Measures was looking at one a while
back, and it came up to over 100 amperes at startup.
Will
On Sun, 30 Jan 2005 14:59:18 -0600, Rich <rdjmgmt@socket.net> wrote:
I am building my first amp , now starting on the power supply. It will
have a 240v 10 amp Powerstat. I have a 4 pole "latching" relay that I
think I will wire so it has a safety drop out , then a DPDT relay with
my soft start resistors. The last variac that I set up to control
voltage for a tesla coil always caused a problem when I plugged it in.
It would blow to 20 amp circuit breaker even though the system pulled
less than an amp at idle. I would have to try several times to get it
to stay on line. The only thing wired in was the variac and a 24v
control transformer.
I am hoping to avoid any problems with the HV system as I build it,
will
the soft start system take care of the instantaneous inductive load
that
it appears I was getting with my other variac ?
Rich / kd0zz
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps
__________ NOD32 1.880 (20040928) Information __________
This message was checked by NOD32 antivirus system.
http://www.nod32.com
-- Using Opera's revolutionary e-mail client:
http://www.opera.com/mail/
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps
Richard L. Measures, AG6K, 805.386.3734. www.somis.org
__________ NOD32 1.880 (20040928) Information __________
This message was checked by NOD32 antivirus system.
http://www.nod32.com
--
Using Opera's revolutionary e-mail client: http://www.opera.com/mail/
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps
|