Re: [Amps] parasitic LC>load?

To: StephenTetorka@cs.com
Subject: Re: [Amps] parasitic LC>load?
From: R.Measures <r@somis.org>
Date: Thu, 11 Nov 2004 16:45:59 -0800
List-post: <mailto:amps@contesting.com>

On Nov 11, 2004, at 1:39 PM, StephenTetorka@cs.com wrote:


Hi all:

Been thinking.

If some of these rigs 'want to' go parasitic, would it be beneficial to help them via a broadband VHF resonant circuit that is coupled to the HF RF tank with that VHF LC discharging into a dissipative side-load?

According to a friend who used to work for an amplifier manufacturer, their 100kW MF-HF model had a resistance-wire hoop suspended in the output compartment to dampen the compartment's VHF resonance.

Regards,
Steve
WA2TAK
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps



Richard L. Measures, AG6K, 805.386.3734. www.somis.org